ID/
Diagnostic
Icons
277
LiquIdent
278
LiquIdent
279
LiquIdent
289
Sound velocity
290
Flow velocity
291
Pressure
292
Kinematic viscosity
293
Auxiliary temperature
294
Sensor temperature
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Action
Value above warning limit. Check process
conditions or align limit to normal operation.
Adjust parameter "Upper warning limit"
Value below warning limit. Check process
conditions or align limit to normal operation.
Adjust parameter "Lower warning limit"
Value below alarm limit. Check process condi-
tions or align limit to normal operation. Adjust
parameter "Lower alarm limit"
Value simulated. Disable 'Simulation' to return
to normal operation.
Value simulated. Disable 'Simulation' to return
to normal operation.
Value simulated. Disable 'Simulation' to return
to normal operation.
Value simulated. Disable 'Simulation' to return
to normal operation.
Value simulated. Disable 'Simulation' to return
to normal operation.
Value simulated. Disable 'Simulation' to return
to normal operation.
Diagnosing and troubleshooting
9.4 Fault codes and corrective actions
Comment
Only hydrocarbon
Only hydrocarbon
Only hydrocarbon
Only hydrocarbon and water
Only hydrocarbon and water
Only hydrocarbon and water
Only hydrocarbon and water
Only hydrocarbon and water
Only hydrocarbon and water