Technical data
10.6 Operating conditions
Description
Ingress protection
Mechanical load
Torques
Table 10- 13 Installation torques
Description
Cable gland to enclosure (Sie-
mens supplied, metric)
Note
NPT glands
When using NPT glands, the user must take care to use the supplied NPT thread adaptors.
10.6
Operating conditions
Table 10- 14 Basic conditions
Description
Ambient temperature
(Humidity max. 90 %)
Ambient temperature
(Humidity max. 90 %)
Climate class
Altitude
Relative humidity
Bump resistance
Shock resistance
Thermal shock
Vibration resistance
EMC performance
120
Specification
IP66/67/NEMA 4X to EN/IEC 60529 (1 meter for 30 min)
18 to 1000 Hz random, 3.17 g RMS, in all directions, to EN/IEC
68-2-36
Torque (Nm)
10
Operation:
Transmitter without display
Display
Storage:
Emission
•
Immunity
•
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Specification
-40 to +60 °C (-40 to +140 °F)
-20 to +60 °C (-4 to +140 °F)
-40 to +70 °C (-40 to +158 °F)
DIN 60721-3-4
Up to 2000 m (6560 ft)
95 %
On request
On request
On request
On request
EN 55011 / CISPR-11
•
EN/IEC 61326-1 (Industry)
•
NAMUR
Operating Instructions, 08/2017, A5E37367739-AC