Siemens SITRANS F series Operating Instructions Manual page 233

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F series:
Table of Contents

Advertisement

Modbus
Data type /
register
Size in bytes
10142
Float / 4
10168
Float / 4
10170
Float / 4
9208
Float / 4
9591
Unsigned / 2
9281
Unsigned / 2
9239
Unsigned / 2
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Parameter
Description
Lower range
Lower process viscosi-
value viscosity
ty value that is mapped
to the lower nominal
range boundary se-
lected by Frequency
value low (9237). Ap-
plicable if Process
value (9204) = 21 or
29.
Upper range
Upper rate of change
value ROC
value that is mapped to
the upper nominal
range boundary se-
lected by Frequency
value high (9235).
Applicable if Process
value (9204) = 36.
Lower range
Lower rate of change
value ROC
value that is mapped to
the lower nominal
range boundary se-
lected by Frequency
value low (9237). Ap-
plicable if Process
value (9204) = 36.
Damping value
Time constant of
damping filter for fre-
quency output signal.
Fail-safe activa-
Fail-safe activation
tion condition
condition.
Fail-safe min.
Minimum time the
time
output stays in fail-safe
behavior.
Fail-safe behav-
Frequency output reac-
ior
tion in case of a fault.
A.9 Modbus holding registers tables
Default value
Value range /
[units]
Setting options
(units regis-
ter)
0.0
-
[m²/s]
(7524)
1.0
-
[m/s²]
(8564)
0.0
-
[m/s²]
(8564)
0.0
0.0 - 100.0
[s]
1
0: Bad status of se-
lected process value
1: Active Mainte-
nance alarm or Fail-
ure (NAMUR)
0
0 - 100
[s]
2
0: Frequency value
low
1: Frequency value
high
2: Last valid value
3: Disabled
4: Custom value
Modbus communication
Access
level
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
231