Modbus communication
A.9 Modbus holding registers tables
Channel 3
Table A- 107 Channel 3
Modbus
Data type /
register
Size in bytes
9103
Float / 4
9128
Unsigned / 2
9140
Unsigned / 2
9269
Float / 4
9272
Unsigned / 2
9287
Unsigned / 4
9200
Float / 4
9203
Unsigned / 2
10503
Float / 4
312
Parameter
Description
Current output
Output current value if
value
configured to current
output.
Error status
Error status if config-
ured to current output.
Status output
Status value if config-
ured to status output.
Pulse status
Amount done if config-
output
ured to pulse output.
Error status
Error status if config-
ured to pulse output.
Pulse counter
Pulse output since
startup.
Frequency
Frequency value if
output value
configured to frequen-
cy output.
Error status
Error status if config-
ured to frequency out-
put.
Current input
Input current value if
value
configured to current
input.
Default value
Value range /
[unit]
Setting options
(unit register)
-
-
-
Bit 0: Overflow
Bit 1: Underflow
Bit 2: Fail mode acti-
vated
Bit 3: Cable break
Bit 4: Output current
cannot be estab-
lished (read back de-
viation > 0.1 mA)
-
0 - 1
-
-
-
Bit 0: The pulse out-
put has reached the
maximum pulse out-
put frequency
Bit 1: Fail mode is
activated
-
-
-
-
-
Bit 0: Overflow
Bit 1: Underflow
Bit 2: Fail mode acti-
vated
-
-
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Access
level
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only