Siemens SITRANS F series Operating Instructions Manual page 170

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F series:
Table of Contents

Advertisement

Modbus communication
A.9 Modbus holding registers tables
Path 4 settings
Table A- 24
Path 4 settings
Modbus
Data type /
register
Size in bytes
1600
Float / 4
1608
Unsigned / 2
1615
Float / 4
1609
Float / 4
Path 5 settings
Table A- 25
Path 5 settings
Modbus
Data type /
register
Size in bytes
1650
Float / 4
1658
Unsigned / 2
168
Parameter
Description
Sensor fre-
Desired sensor frequency for
quency
path 4.
Path geometry
The number of crossings the
signal makes through the pipe
(Reflect or direct geometry for
path 4).
E.g.:
Z path = 1
V path = 2
W path = 4
Spacing offset
Spacing offset (LTN) between
clamp-on sensors for path 4.
Path weight
Fixed weighting factor associ-
ated with path 4.
For clamp-on systems the in-
stalled paths weightings should
be identical but not zero.
For inline systems the sum of
the installed paths weightings
should be 1.0.
Parameter
Description
Sensor fre-
Desired sensor frequency for
quency
path 5.
Path geometry
The number of crossings the
signal makes through the pipe
(Reflect or direct geometry for
path 5).
E.g.:
Z path = 1
V path = 2
W path = 4
Default value
Value range /
[units]
Setting options
(units regis-
ter)
1100000
80000.0 -
[Hz]
4000000.0
1
1 - 10
0.0
-100.0 - 100.0
[m]
(8556)
1.0
0.01 - 2.0
Default value
Value range /
[units]
Setting options
(units regis-
ter)
1100000
80000.0 -
[Hz]
4000000.0
1
1 - 10
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Access
level
Read /
write
Read /
write
Read /
write
Read /
write
(Expert)
Access
level
Read /
write
Read /
write