Modbus
Data type /
register
Size in bytes
1223
Unsigned / 2
1224
Unsigned / 2
Process medium characteristics
Table A- 17
Process medium characteristics
Modbus
Data type /
register
Size in bytes
1825
Float / 4
1701
Float / 4
1703
Float / 4
1705
Float / 4
1707
Float / 4
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Parameter
Description
Downstream
Compensation for
pipe geometry
downstream pipe ge-
ometry.
Downstream
The distance to the
distance
downstream flow dis-
turbance in multiples of
inner pipe diameter.
Parameter
Description
Expected sound
Expected sound veloci-
velocity
ty in the medium at
medium temperature.
Fixed medium
Fixed medium temper-
temperature
ature value used for
compensation.
Fixed process
Fixed process pressure
pressure
value used for com-
pensation.
Fixed process
Fixed process viscosity
viscosity
value used for com-
pensation.
Fixed process
Fixed process density
density
used for compensation.
A.9 Modbus holding registers tables
Default value
Value range /
[units]
Setting options
(units regis-
ter)
0
0: Straight run
1: Single elbow
2: Double elbow (in-
plane)
3: Double elbow (out-
of-plane)
4: Reducer
5: Expansion
0
0 - 40
Default value
Value range /
[units]
Setting options
(units regis-
ter)
1500.0
100.0 - 2500.0
[m/s]
(7648)
20
-273 - 400
[°C]
(7700)
700000.0
0.0 - 1E+8
[Pa]
(8015)
0.000001
0.0 - 5000.0
[m
/s]
2
(7524)
1000.0
0.0 - 2000.0
[kg/m
]
3
(7600)
Modbus communication
Access
level
Read /
write
Read /
write
Access
level
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
159