Siemens SITRANS F series Operating Instructions Manual page 319

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F series:
Table of Contents

Advertisement

Process value 3
Table A- 111 Process value 3
Modbus
Data type /
register
Size in bytes
11202
Unsigned / 2
11298
Float / 4
11300
String / 32
11280
Float / 4
11282
String / 32
11206
Unsigned / 2
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Parameter
Description
Process value
Process value config-
ured to be monitored
Maximum value Drag indicator of max-
imum value specified
by Process value
(11202)
Maximum value
Shows timestamp of
timestamp
recorded maximum
value specified by
Process value (11202)
Minimum value
Drag indicator of mini-
mum value specified
by Process value
(11202)
Minimum value
Shows timestamp of
timestamp
recorded minimum
value specified by
Process value (11202)
Reset logging
Command to reset the
drag pointers to the
process value's default
value.
A.9 Modbus holding registers tables
Default value
Value range /
[unit]
Setting options
(unit register)
Disabled
3000: Volume flow
3004: Mass flow
3006: Sound velocity
3008: Flow velocity
3040: Density
3042: Medium tem-
perature
3044: Pressure
3046: Viscosity
3048: RTD tempera-
ture 1
3050: RTD tempera-
ture 2
65535: Disabled
Min. floating
-
point value
[units depend-
ing on pro-
cess value]
-
Max. floating
-
point value
[units depend-
ing on pro-
cess value]
-
-
1: reset
Modbus communication
Access
level
Read /
write
Read
only
Read
only
Read
only
Read
only
Write
only
317

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fst030

Table of Contents