Siemens SITRANS F series Operating Instructions Manual page 164

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F series:
Table of Contents

Advertisement

Modbus communication
A.9 Modbus holding registers tables
Modbus
Data type /
register
Size in bytes
1312
Float / 4
1314
Float / 4
1316
Float / 4
1318
Float / 4
1320
Float / 4
1322
Unsigned / 2
1711
Float / 4
1713
Unsigned / 2
162
Parameter
Description
Sensor crystal
Length of the
projection
crystal projec-
tion onto the
emitting surface
of the sensor.
Sensor phase
The velocity at
velocity
which the wave
fronts traverse
the interface
between the
wedge and the
pipe.
Sensor inactive
The part of the
wedge
wedge that is
not part of the
sound path.
Sensor fixed
Fixed time in
time
sensor wedge.
Mounting hole
Distance be-
offset
tween spacer
hole and sensor
front face.
Pipe travel time
Designated
multiplier on the
crystal projec-
tion value used
in formula for
calculating pipe
travel.
Temperature
Sensor tempera-
compensation
ture compensa-
factor
tion slope factor.
Reference
Sensor refer-
temperature
ence (nominal)
temperature.
Default value
Value range /
[units]
Setting options
(units regis-
ter)
0.03409
0.0 - 3.0
[m]
(8556)
3695.5
2000.0 - 10000.0
[m/s]
(7648)
0.00076
0.0 - 0.05
[m]
(8556)
10.61E-6
2.0E-6 - 200.0E-6
[s]
0.00953
0.0 - 0.05
[m]
(8556)
0
0 - 200
0.00063761
0.0001 - 0.0009
[1/K]
0
0: 21 °C
1: 60 °C
2: 93 °C
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Access
level
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write
Read /
write