Modbus
Data type /
register
Size in bytes
2048
Float / 4
2054
Float / 4
Channel 5 RTD configuration settings
Table A- 68
Channel 5 RTD configuration settings
Modbus
Data type /
register
Size in bytes
2102
Float / 4
2106
Float / 4
2108
Float / 4
Channel 6 RTD configuration settings
Table A- 69
Channel 6 RTD configuration settings
Modbus
Data type /
register
Size in bytes
2104
Float / 4
2110
Float / 4
2112
Float / 4
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Parameter
Description
Fail-safe value
Input value in case of a
Xdcr tempera-
fault and when Fail-
ture
safe behavior is con-
figured to 1. Applicable
if process value (2002)
= 5.
Fail-safe value
Input value in case of a
auxiliary tem-
fault and when Fail-
perature
safe behavior is con-
figured to 1. Applicable
if process value (2002)
= 6.
Parameter
Description
RTD wire re-
Resistance of cables in
sistance
a 2 wire RTD system.
Offset
Calibration offset.
Slope
Calibration slope.
Parameter
Description
RTD wire re-
Resistance of cables in
sistance
a 2 wire RTD system.
Offset
Calibration offset.
Slope
Calibration slope.
A.9 Modbus holding registers tables
Default value
Value range /
[units]
Setting options
(units regis-
ter)
20.0
-50.0 - +250.0
[°C]
(7700)
20.0
-50.0 - +250.0
[°C]
(7700)
Default value
Value range /
[units]
Setting options
(units regis-
ter)
0
0.0 - 50.0
[ohm]
0
-100.0 - +100.0
[°C]
(7700)
1.0
0.5 - 2.0
Default value
Value range /
[units]
Setting options
(units regis-
ter)
0
0.0 - 50.0
[ohm]
0
-100.0 - +100.0
[°C]
(7700)
1.0
0.5 - 2.0
Modbus communication
Access
level
Read /
write
Read /
write
Access
level
Read /
write
Read /
write
Read /
write
Access
level
Read /
write
Read /
write
Read /
write