Modbus Holding Registers Tables; Process Values - Siemens SITRANS F series Operating Instructions Manual

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F series:
Table of Contents

Advertisement

A.9

Modbus holding registers tables

In the following the Modbus RTU holding registers available for SITRANS FS430 are
described.
Note
All Write parameters require password access.
Note
In case of error message "Check if the device is set to CT or SIL Operation mode", please
check for the following root causes:
- The device is set to CT mode
- The device is set to SIL mode
- The used Modbus register address is wrong
A.9.1

Process values

Table A- 8
Process values for standard applications
Modbus
Data type /
register
Size in bytes
3000
Float / 4
3004
Float / 4
3008
Float / 4
3006
Float / 4
3040
Float / 4
3044
Float / 4
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Parameter
Description
Volume flow
Measured volume flow
Mass flow
Measured mass flow
Flow velocity
Measured liquid flow
velocity
Sound velocity
Measured fluid sound
speed
Density
Liquid density
Pressure
Process pressure
A.9 Modbus holding registers tables
Default value
Value range /
[units]
Setting options
(units regis-
ter)
-
-
[m³/s]
(7500)
-
-
[kg/s]
(7400)
0.0
-
[m/s]
(8014)
1500.0
-
[m/s]
(7684)
0.0
-
[kg/m
]
3
(7600)
-
-
[Pa]
(7548)
Modbus communication
Access
level
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only
133