Siemens SITRANS F series Operating Instructions Manual page 101

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F series:
Table of Contents

Advertisement

ID/
Diagnostic
Icons
143
Totalizer 2
144
Totalizer 3
145
Totalizer 3
146
Totalizer 3
147
Totalizer 3
148
Transmitter temperature
149
Transmitter temperature
150
Sensor signal disrupted
151
SensorFlash
152
SensorFlash
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Action
Value below alarm limit. Check process condi-
tions or align limit to normal operation. Adjust
parameter 'Lower alarm limit'
Value above alarm limit. Check process condi-
tions or align limit to normal operation. Adjust
parameter 'Upper alarm limit'
Value above warning limit. Check process
conditions or align limit to normal operation.
Adjust parameter 'Upper warning limit'
Value below warning limit. Check process
conditions or align limit to normal operation.
Adjust parameter 'Lower warning limit'
Value below alarm limit. Check process condi-
tions or align limit to normal operation. Adjust
parameter 'Lower alarm limit'
Transmitter temperature above alarm limit.
Relocate the device if possible or lower the
ambient temperature enough to cool the de-
vice. Inspect the device for heat-related dam-
age.
Transmitter temperature below alarm limit.
Relocate the device if possible or raise the
ambient temperature enough to heat the de-
vice. Inspect the device for cold-related dam-
age.
Turn off the power. Unplug and reconnect the
sensor cable. Restore power. If the error still
exists, contact your local Siemens representa-
tive.
Backup disabled. Another SensorFlash was
inserted. To acknowledge please copy the
configuration from the SensorFlash to the
device, remove this Sensorflash and insert the
original SensorFlash.
Backup disabled. Another SensorFlash was
inserted. To acknowledge please copy the
configuration from the SensorFlash to the
device, remove this Sensorflash and insert the
original SensorFlash.
Diagnosing and troubleshooting