Inputs And Outputs - Siemens SITRANS F series Operating Instructions Manual

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F series:
Table of Contents

Advertisement

Modbus communication
A.9 Modbus holding registers tables
Modbus
Data type /
register
Size in bytes
3280
Float / 4
3282
Float / 4
A.9.7.4

Inputs and outputs

General
Table A- 105 General
Modbus
Data type /
register
Size in bytes
8799
Unsigned / 2
310
Parameter
Description
DSL temp min
Warranty pointer for
value
DSL temperature.
Minimum DSL temper-
ature encountered
during the device life-
time.
DSL temp max
Warranty pointer for
value
DSL temperature.
Maximum DSL tem-
perature encountered
during the device life-
time.
Parameter
Description
Reset pulse
Command to reset
counter
pulse counters.
Default value
Value range /
[unit]
Setting options
(unit register)
200.0
-200.0 to +800.0
[°C]
(1001)
-200.0
-200.0 to +800.0
[°C]
(1001)
Default value
Value range /
[unit]
Setting options
(unit register)
0
1: Reset all pulse
totalizers and pulse
counts
2: Reset pulse total-
izer in channel 2
3: Reset pulse total-
izer in channel 3
4: Reset pulse total-
izer in channel 4
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
Operating Instructions, 08/2017, A5E37367739-AC
Access
level
Read /
write
Read /
write
Access
level
Write
only