MSD-62 Series User's Guide

9.14.3 Command link

Menu
Top→PRESET COMMAND→COMMAND LINK
Setting for
[Table 9.30] Control command execution condition
Setting value OFF [Default], COMMAND 1 to COMMAND 32
The MSD has 180 command execution conditions as shown below. If these execution conditions are met,
control commands which are associated beforehand will be executed. One execution condition can be
associated to up to 10 commands. If multiple commands are associated, commands are executed in order of
registration. If the same command is associated multiple times, it is repeatedly executed.
Control command execution button can be toggled.
Set "TOGGLE" to "ON" to enable PLANE-B, and then you can select execution plane ("AUTO", "A(PLANE-A)",
or "B(PLANE-B)") at the time of power ON from "STARTUP". If you select "AUTO", the condition at the time of
power OFF will be maintained.
Press the MENU/SET key to apply the setting.
CMD1
CMD2
CMD3
CMD4
CMD5
CMD30
CMD31
CMD32
126
Control commands
Linking
Execution order
[Fig. 9.27] Command link
Execution condition
POWER ON
DISPLAY1 POWER ON
1st
COMMAND 3
COMMAND 4
2nd
COMMAND 1
3rd
4th
5th
6th
7th
8th
9th
10th
st
th
Default: OFF for 1
to 10