9.13.3 TCP port number
Menu
Top→LAN→PORT NUMBER
Setting for
Each connection
Setting value [Table 9.22] TCP port number
Communication command control
WEB browser control
[Default]
Connections 1 to 3 = 1100; Connections 4 to 6 = 23;
Connections 7, 8 = 80
You can set the TCP port number to control the MSD externally.
This setting will valid if "RECEIVER" is selected for "9.13.2 LAN operation mode".
Each connection will be divided into connections for communication command control and WEB browser
depending on the set port numbers.
Press the MENU/SET key to apply the setting.
9.13.4 MAC address
Menu
Top→LAN→MAC ADDRESS
You can display the MAC address.
9.13.5 Setting HDBaseT LAN
Menu
Top→LAN→HDBASET LAN
Setting for
2 HDBaseT output channels
MSD-6203: OUT1/OUT2, and OUT3
MSD-6204: OUT1/OUT2 and OUT3/OUT4
MSD-6206: OUT1/ OUT2, OUT3/OUT4, and OUT5/OUT6
MSD-6208: OUT1/OUT2, OUT3/OUT4, OUT5/OUT6, and OUT7/OUT8
Setting value ON [Default], OFF
You can enable/ disable the LAN of HDBaseT output connector.
Note:
Reboot the MSD to apply the setting.
[Table 9.22] TCP port number
For
23, 1100, 6000 to 6999
80, 5000 to 5999
MSD-62 Series User's Guide
Setting value
【See: 9.13 LAN】
115