If only start position is changed, "NORMAL END" is displayed. If active area is changed if "NORMAL MODE"
is selected or if "NEXT ASPECT" or aspect ratio is specified directly, the set resolution is displayed.
If there is no input signal on the input channel it shows "NOT AVAILABLE NOW" on the front VFD screen.
Press the "MENU/SET" key to perform automatic measurement.
Note:
In case the aspect ratio does not match or video is displayed on the position far from the correct position, set
the input timing in, "9.8.2 The total number of horizontal dots", "9.8.3 Start position", and "9.8.4 Active
area".
■ Operation from front keys
You can execute the automatic measurement in "NORMAL MODE" by pressing an IN7 or IN8 key (analog
input only) for two seconds or longer. If you want to execute the automatic measurement in "NEXT ASPECT",
press the same key for five seconds or longer.
Once automatic measurement is executed, it will be executed just by pressing the desired input channel
selection key (you do not have to press and hold the key). Five seconds after the last automatic measurement,
this mode will be disabled.
Pressing and holding key
[IN8 AUTO SETUP]
1024x 768 60.00Hz
2 sec.
2 sec.
Automatic measurement starts (NORMAL MODE)
5 sec.
2 sec.
[Fig. 9.17] Automatic measurement using front key
【See: 9.7.5 Selecting signal of DVI input connector】
5 sec.
7 sec.
Automatic measurement starts
(NEXT ASPECT)
Disabled 5 sec. after last
measurement
Automatic measurement restarts by pressing
key within 5 sec. after the last measurement
MSD-62 Series User's Guide