IDK MSD-6203 User Manual page 125

4k supported digital multi switcher msd-62 series
Hide thumbs Also See for MSD-6203:
Table of Contents

Advertisement

■ Mask data
Each bit of the received data is ANDed to each bit of mask data, and the result will be compared with the
reply command data. Since "FF" is set by factory default, you do not need to change the mask data
normally. Only to determine the status using bits of the received data, change the setting.
[If ASCII codes (text) are replied from an external device]
Since the received data and "Reply command data" are compared without any changes, set "MASK" to
"FF". (If you set "COMMAND INPUT MODE" of reply command to "ASCII", it is automatically set to "FF".)
For example, if "0" of ASCII codes ("30" in hex) is replied:
(Received data)
(Reply command data)
DATA1:30 00 00 00 00
MASK1:FF FF FF FF FF
[If status is determined using bits of the received data]
Set only bits that determine the Mask data to "1" and set other bits to "0".
For example, if determining status using the second bit from the left:
(Received data)
(Reply command data)
(Received data)
(Reply command data)
DATA1:40 00 00 00 00
MASK1:40 FF FF FF FF
Binary
00110000
& (MASK)
00110000
Binary
11111111
& (MASK)
01000000
Binary
10111111
& (MASK)
01000000
MSD-62 Series User's Guide
Binary
Hexadecimal
11111111
=30
=30 matched
Binary
Hexadecimal
01000000
=40
=40 matched
Binary
Hexadecimal
01000000
=00
=40 not matched
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msd-6208Msd-6204Msd-6206

Table of Contents