Commissioning
5.2 Basic commissioning
5.2.5
Basic commissioning with IOP
Basic commissioning wizard
1.
2.
3.
4.
98
Select "Basic Commissioning..." from the Wizards
menu.
Select "Yes" or "No" to a factory reset.
It is recommended that a factory reset is performed to
ensure that the converter is in a known and stable state
prior to commissioning.
Once "Yes" is selected the IOP will initiate a factory
reset immediately.
On completion of the factory reset the "Application
Class" is selected.
In this example the "Standard Drive Control" is selected.
Select the correct Motor Data for your Inverter and at-
tached motor.
This data is used to calculate the correct speed and
displayed values for the application.
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD