Functions
8.9 Application-specific functions
See also
Switching units with STARTER (Page 215)
Reference variables for unit changeover
p2000 Reference frequency/speed
p2001 Reference voltage
p2002 Reference current
p2003 Reference torque
r2004 Reference power
8.9.2.1

Changing over the motor standard

You change over the motor standard using p0100. The following applies:
● p0100 = 0: IEC motor (50 Hz, SI units)
● p0100 = 1: NEMA motor (60 Hz, US units)
● p0100 = 2: NEMA motor (60 Hz, SI units)
The parameters listed below are affected by the changeover.
Table 8- 18
P no.
r0206
p0307
p0316
r0333
p0341
p0344
r1969
*) Factory setting
8.9.2.2

Changing over the unit system

You change over the unit system using p0505. The following selection options are available:
● p0505 = 1: SI units (factory setting)
● p0505 = 2: SI units or % relative to SI units
214
Variables affected by changing over the motor standard
Designation
Power Module rated power
Rated motor power
Motor torque constant
Rated motor torque
Motor moment of inertia
Motor weight (for thermal motor type)
Speed_cont_opt moment of inertia determined
0*
)
kW
kW
Nm/A
Nm
kgm
2
kg
kgm
2
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
Unit for p0100 =
1
2
HP
kW
HP
kW
lbf ft/A
Nm/A
lbf ft
Nm
lb ft
kgm
2
2
Lb
kg
lb ft
kgm
2
2