Adapt inputs and outputs

This chapter describes how you adapt the function of individual digital and analog inputs and
outputs of the inverter.
See also
Interconnecting signals in the inverter (Page 321)
Deadband of the analog inputs (Page 123)
Commissioning (Page 83)
Figure 6-1
Digital inputs
Table 6- 1
BI
p0810 Command data set selection CDS bit 0
p0840 ON/OFF1
p0844 OFF2
p0848 OFF3
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
Internal interconnection of the inputs and outputs
Binector inputs (BI) of the inverter (selection)
Significance
Changing the function of the digital input
Interconnect the status parameter of the digital input with a bi-
nector input of your choice.
Binector inputs are marked with "BI" in the parameter list of the List
Manual.
BI
p1036 Motorized potentiometer, setpoint, lower
p1055 Jog bit 0
p1056 Jog bit 1
p1113 Setpoint inversion
Significance
6
117