A.4 Frequently required parameters
Use the factory settings (where possible)
In simple applications, the inverter already functions with its factory settings.
Only basic commissioning is required ... for simple, standard applications
Most standard applications function after just a few adaptations made during the basic
commissioning.
A.3.2

Parameter

Parameters are the interface between the firmware of the converter and the commissioning
tool, e.g. an Operator Panel.
Adjustable parameters
Adjustable parameters are the "adjusting screws" with which you adapt the converter to its
particular application. If you change the value of an adjustable parameter, then the converter
behavior also changes.
Adjustable parameters are shown with a "p" as prefix, e.g. p1082 is the parameter for the
maximum motor speed.
Display parameters
Display parameters allow internal measured quantities of the converter and the motor to be
read.
The Operator Panel and STARTER represent display parameters with an "r" prefix, for
example, r0027 is the parameter for the converter output current.
A.4

Frequently required parameters

Parameters that are commonly required
Table A- 2
How to switch to commissioning mode or restore the factory setting
Parameter
Description
p0010
Commissioning parameters
0: Ready (factory setting)
1: Carry out basic commissioning
3: Perform motor commissioning
5: Technological applications and units
15: Define number of data records
30: Factory setting - initiate restore factory settings