Siemens Sinamics G110M Original Instructions Manual page 295

Distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Explanation of status LEDs
An explanation of the various states indicated by the LEDs are given in the tables below.
Table 11- 1
Description of general status LEDS
LED
RDY
GREEN - On
GREEN - Flashing slowly
RED - On
RED -Flashing slowly
RED - Flashing quickly
RED - Flashing quickly
RED - Flashing quickly
Table 11- 2
Description of fieldbus communications LED
BF LED
Off
RED - Flashing slowly
RED - Flashing quickly
Table 11- 3
Description of SAFE LED
SAFE LED
YELLOW - On
YELLOW - Flashing
slowly
YELLOW - Flashing
quickly
Table 11- 4
Description of PROFINET communications LED
PROFINET LED
LNK - On
LNK - Off
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
BF
-
-
ORANGE - flashing
slowly
RED - flashing slowly
-
RED - On
RED - flashing quickly
Description of function
Cyclic data exchange (or fieldbus not in use - p2030 = 0)
Bus fault - configuration fault
Bus fault:
- no data exchange
- baud rate search - cannot detect the correct baud rate
- no connection - the connection between the Inverter and PLC has been lost
Description of function
Safety function is enabled - but not active
Safety function is active - no safety function faults have occurred
The converter has detected a safety function fault and initiated a stop re-
sponse
Description of function
Link is active
Link inactive with no data being transferred
Description of function
Ready for operation (no active fault)
Commissioning or reset of factory settings
Firmware update in progress
Firmware updated is complete - power ON reset required
General fault condition
Fault occurred during firmware update
Incompatible firmware or incorrect memory card
Alarms, faults and system messages
11.3 Status LED overview
295

Advertisement

Table of Contents
loading