Data backup and series commissioning

9.3 Other ways to back up settings

PC/PG → inverter
Procedure
To transfer the settings, proceed as follows:
1. Go online with STARTER :
2. Select the button "Download project to target system":
3. To save the data in the inverter, select the "Copy RAM to ROM" button:
4. Go offline with STARTER :
You have transferred the settings.
9.3
Other ways to back up settings
In addition to the default setting, the inverter has an internal memory for backing up three
other settings.
On the memory card, you can back up 99 other settings in addition to the default setting.
You will find additional information on the Internet at: Memory options
(http://support.automation.siemens.com/WW/view/en/43512514).
9.4

Write and know how protection

The inverter offers the option to protect configured settings from being changed or copied.
Write protection and know-how protection are available for this purpose.
9.4.1

Write protection

Write protection prevents inadvertently changing inverter settings. If you are working with a
PC tool, such as STARTER, then write protection is only effective online. The offline project
is not write-protected.
Write protection is applicable for all user interfaces:
● BOP-2 and IOP operator panels
● STARTER or Startdrive PC tool
● Parameter changes via a fieldbus
The write protection is not password-protected.