12.3

SINAMICS G110M specifications

Power Module Specifications
Note
UL certified Fuses must be used
UL certified Fuses must be used" it should state "In order that the system is in compliance
with UL requirements, UL listed class J fuses must be used. The fuse rating of these fuses
must be equal to or less that the ratings given in Table 4-2 Rated Output, Input and Fuses
(Page 57).
IP protection of the system
The Power Module and the Terminal Unit (which includes the Control Module) when fully
assembled and attach to the motor has an IP rating of IP65/66 depending on the version of
the Control Module.
Minimum required resistance for the braking resistors
For each Power Module rating there is a minimum resistance required for the braking
resistors associated with the specific power modules, please see the table below for further
details.
Table 12- 3
Frame
size
FSA
FSA
FSA
FSA
FSB
FSB
FSB
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
PM240M Power Modules - minimum resistance for braking resistors
Rated output
Rated output current
power (kW)
(A)
based on High Overload (HO)
0.37
1.3
0.75
2.2
1.1
3.1
1.5
4.1
2.2
5.6
3.0
7.3
4.0
8.8
12.3 SINAMICS G110M specifications
Article number
Minimum resistance for
braking resistors
6SL3517-1BE11-
200 Ω
3AM0
6SL3517-1BE12-
200 Ω
3AM0
6SL3517-1BE13-
200 Ω
3AM0
6SL3517-1BE14-
200 Ω
3AM0
6SL3517-1BE16-
60 Ω
3AM0
6SL3517-1BE17-
60 Ω
7AM0
6SL3517-1BE21-
60 Ω
0AM0
Technical data
305