Main Motor - Canon imageFORMULA DR-X10C Service Manual

Hide thumbs Also See for imageFORMULA DR-X10C:
Table of Contents

Advertisement

3. Main Motor

1) Remove the left cover.
(Page 3-5)
2) Remove the power supply PCB (with a
panel).
(Page 3-14)
3) Remove 2 screws
move the tension plate
3
and belt
4
.
Figure 3-307
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
(TP head) and re-
2
, tension spring
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4) Remove 3 cable holders
the cable
2
from the mounting plate.
Remove 3 screws
the mounting plate
turn it over while holding it with a hand.
Note: Do not pull it excessively because a
cable is connected.
Figure 3-308
5) Remove the cable holder and connector of
the cable
1
and remove the main motor
unit
2
from the main body.
Note: The DC power supply connector for the
cable has a lock.
Figure 3-309
1
and remove
3
(round tips), pull out
4
(with a motor), and
3-15

Advertisement