Main Motor - Canon imageFORMULA DR-M140 Service Manual

First edition
Hide thumbs Also See for imageFORMULA DR-M140:
Table of Contents

Advertisement

2. Main Motor

1) Remove the control PCB (with mounting
plate).
(Page 3-4)
2) Remove the main motor cable
the cable holder, and remove it from the
base unit.
Figure 3-205
3) Remove
the
self-tapping), and then remove the main
motor
(with belt).
2
Figure 3-206
COPYRIGHT © CANON ELECTRONICS INC. 2011
from
1
2
screws
(M3,
1
CANON DR-M140 FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4) Remove the belt
Figure 3-207
Notes on assembling
Align the edge
the hole in the base, and mount the
motor while inserting the position setting
pin
into the hole in the mounting
3
plate so that the two edges
grounding plate touch the inside of the
motor mounting plate.
Do not get the cables caught in parts.
Figure 3-208
and gears
.
1
2
of the gear shaft with
1
of the
2
3-5