CHAPTER 3 DISASSEMBLY & REASSEMBLY

9. Reverse Roller

Note: The right and left reverse rollers are
same parts. Since the disassembling
procedure is the same and the con-
figuration is symmetrical, only the
disassembling procedure of the right
reverse roller is shown here. Disas-
semble the left reverse roller by
referring to the disassembling proce-
dure of the right reverse roller.
1) Remove the pickup unit.
(Page 3-55)
2) Remove the belt
parts
2
of the pulley and remove the
pulley. Then, remove both shaft guides
from the mounting plate and remove the
reverse roller
.
4
Figure 3-814
Notes on assembling
Match the fitting shapes of the shaft guide
and mounting plate. Assemble the shaft,
roller and pulley by aligning the direction of
the D-shapes of the shaft, roller and pulley.
3-56
1
. Unhook the fitting
COPYRIGHT © CANON ELECTRONICS INC. 2008

10. Roller Holder

1) Remove the pickup unit.
(Page 3-55)
2) Remove the pickup roller and feed roller.
3) Remove the spring
3
(1 each) on both sides of the reverse
roller unit.
Note: A pin is mounted on the pulley. Do not
lose it.
3
4) Remove the reverse roller unit
gear
2
rings
3
move 2 shaft supports
1
, belt
2
Figure 3-815
on both sides. Remove 2 stop
and pull out the shaft
.
5
Figure 3-816
CANON DR-X10C FIRST EDITION
and pulley
and
1
. Re-
4