6) Remove the cable from cable guides on
the bottom plate. Remove 2 screws
(M3, TP head) on the both sides and pull
out the reading unit (lower)
Note: Do not pull it excessively because a
cable is connected to it.
Coil springs are mounted in the lower
part of the reading unit fixing part. Do
not lose it.
Figure 3-504
7) Remove 3 connectors
reading unit (lower)
Figure 3-505
Notes on assembling
Do not nip the cable. Insert the cable into
the cable holder of the reading unit and the
cable guide of the bottom plate.
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
2
.
and remove the
1
2
.
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY

2. Reading PCB

1) Remove the reading unit (lower).
(Page 3-32)
2) Remove 3 connectors
cable from the cable guides of the 2 cable
covers
2
.
Figure 3-506
3) Unhook 2 pairs of the fitting parts
remove the cable cover
way, remove the cable cover on the op-
posite side.
Figure 3-507
1
and remove the
and
1
2
. In the same