Upper Unit-3 (Feed System); Platen Roller; Registration Roller - Canon imageFORMULA DR-X10C Service Manual

Hide thumbs Also See for imageFORMULA DR-X10C:
Table of Contents

Advertisement

VIII. UPPER UNIT-3 (FEED SYSTEM)

1. Platen Roller

1) Remove the screws
sides. Then, rotate the platen roller
the direction of the arrow, align the bearing
3
with the side plate notch
move the platen roller.
Figure 3-801
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
(stepped) on both
2
in
4
, and re-
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY

2. Registration Roller

1) Remove the entrance upper unit.
(Page 3-40)
2) Open the ends (marked with
bearing holders
parts and remove the registration roller unit
.
2
Note: Since the coil spring in the registration
roller unit may be detached, do not lose
it.
Note: Since the entire registration roller unit
and a single registration roller are set as
service parts, select them as required.
Figure 3-802
) of both
1
and unhook the fitting
3-51

Advertisement

Table of Contents
loading