2. Feed Motor

Note: The feed motor and main motor have
different cable lengths. The longer one
is the feed motor.
1) Remove the lower cover.
(Page 3-3)
2) Disconnect the feed motor
on the control PCB. Remove the 2
screws
(M3, with 2 washers), and
2
then remove the feed motor and timing
belt
.
3
Note: The pulley and gear detach at the
same time. The motor is configured
with a cable attached.
Figure 3-304
Notes on assembling
After assembly, the leading edge of the
grounding plate of the PCB mounting
plate should touch the motor.
3-10

3. Main Motor

Note: The feed motor and main motor have
1) Remove the lower cover.
connector
2) Disconnect
1
Note: The motor is configured with a cable
COPYRIGHT © CANON ELECTRONICS INC. 2011
different cable lengths. The shorter
one is the main motor.
(Page 3-3)
the
connector on the control PCB. Remove
the 2 screws
(M3, with 2 washers),
2
and then remove the main motor.
attached.
Figure 3-305
Notes on assembling
To adjust the belt tension correctly,
mount the belt and then affix the screw
on the side (round hole) of the base
indicated by "1". Next, affix the screw on
the side (long hole) indicated by "2".
After assembly, the leading edge of the
grounding plate of the PCB mounting
plate should touch the motor.