CHAPTER 3 DISASSEMBLY & REASSEMBLY
10. Ultrasonic Drive PCB
1) Remove the entrance lower guide unit.
(Page 3-24)
2) Remove 2 screws
the frame detection unit
shift it. Then, pull out the ultrasonic drive
PCB unit
3
.
Note: Do not pull it excessively because a
cable is connected to the back side of
both units.
Figure 3-318
3) Remove the connector
ultrasonic drive PCB unit
main body.
Figure 3-319
3-20
1
(long stepped), lift
2
a little and
and remove the
1
from the
2
COPYRIGHT © CANON ELECTRONICS INC. 2008
4) Remove the transparent guide plate
Figure 3-320
5) Remove 2 screws
and while unhooking 3 pairs of the fitting
parts
2
, remove the ultrasonic drive PCB
3
.
Note: Since the ultrasonic sensor and LED
are mounted on the back side of the
PCB, do not hit them against the
mounting plate.
Figure 3-321
1
.
1
(M3, round tips),
CANON DR-X10C FIRST EDITION