CHAPTER 5 TROUBLESHOOTING
VII. AFTER REPLACING PARTS
Some of the parts used in this machine
require adjustments and settings after being
replaced or disassembled/reassembled. The
replacement parts are shown below.
Check document feed and images after
the replacement or disassembly/reassembly
of the parts.
1) Control PCB
i) Perform "All Adjustment" of the service
mode.
ii) Change the value by the "Counter" of the
service mode.
2) Reading unit
Perform "All Adjustment" in the service
mode.
3) Frame detection unit
Perform "Regist Adjustment" in the service
mode.
4) Registration-related parts
When replacing or reassembling the ul-
trasonic sensor PCB and ultrasonic drive
PCB on which a registration sensor is built,
perform "Regist Adjustment" in the service
mode.
5) Consumable parts (service parts)
When consumable parts, such as platen
rollers, which are replaced by the service
technician, are replaced, set the number of
sheets fed during replacement by the
"Counter" of the service mode.
5-38