5. Exhaust Fan

1) Remove the main motor unit.
(Page 3-15)
2) Remove the connector
(M4×25) and remove the exhaust fan
Figure 3-312
Notes on assembling
Assemble the exhaust fan so that its dis-
play label faces outward.
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
and 2 screws
2
3
.
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY

6. Tray Detection PCB

1) Remove the entrance lower guide unit.
(Page 3-24)
2) Remove the cable
(TP head) and remove the tray detection
PCB
3
(with a mounting plate).
Figure 3-313
3) Remove 2 screws (M3, round tip) and
remove the mounting plate.
1
and 2 screws
2
3-17