Canon imageFORMULA DR-X10C Service Manual page 183

Hide thumbs Also See for imageFORMULA DR-X10C:
Table of Contents

Advertisement

iv) Data of the outside frame of the paper
is memorized and displayed in the dis-
play section. The area enclosed by a
red line and a blue line shows the out-
side frame of the paper. One scale is 10
mm.
Figure 5-321
Note: When [Renew] is not selected, but the
[Read] button is selected, the outside
frame that was previously recorded is
displayed.
Note: When [Save Log] is selected, outside
frame data can be saved in the com-
puter for servicing, which has been
connected. It is not normally used, but
is used only if an instruction for
analysis is given.
2) Monitor
If a finger or a sheet of paper is placed on
the frame detection section, detected data
is displayed. Even when the upper unit is
open, data is displayed due to outside
daylight. If the upper unit is closed, select
the [Led] button and light the LED.
Frame detection section
148
0
L
Figure 5-322
COPYRIGHT © CANON ELECTRONICS INC. 2008
R
338
161
CANON DR-X10C FIRST EDITION
CHAPTER 5 TROUBLESHOOTING
Examples of display are shown below.
i) Put 2 fingers on the left detection section.
148
0
161
Figure 5-323
ii) Place a sheet of paper (A4 size) at the
center.
0
Figure 5-324
338
338
5-21