7. Frame Detection Unit

1) Remove the right cover.
(Page 3-3)
2) Remove 2 flat cables
nectors and cable holders.
Figure 3-523
3) Remove 2 screws
remove the frame detection unit
Note: Since the flat cables are connected to
the back side, remove them being
careful not to damage it.
Figure 3-524
Note: If parts, such as a frame detection guide
and ink drain pad are removed, perform
the following procedure. However, be
careful not to allow dust to enter the
parts.
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
from the con-
1
(long stepped) and
2
.
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4) Unhook 7 pairs of the fitting parts
remove the frame detection guide
Figure 3-525
5) Remove the ink drain pad
the thin tip of a tool.
Note: Do not stain the surface of the sensor
2
. If ink is collected in the pad, provide
paper and a storage bag to prevent
soiling of your fingers or the periphery.
Do not remove the sensor from the
case.
Figure 3-526
Notes on assembling
Remove dust from the surfaces of the
sensor with an air blower before assem-
bling the frame detection guide.
Push all fitting parts until they snap on.
There must be no lifts or gaps.
They must not nip the flat cable.
1
and
2
.
1
by inserting
3-39