13) Reserve a space for placing the removed
upper unit, lift the front of the upper unit
slightly, put one hand under the bottom
and hold it. While holding the rear side of
the upper unit with the other hand, lift and
rotate the front of the upper unit, and
remove it so that the side of the upper unit
does not hit and damage the side of the
base unit.
Figure 3-616
Notes on assembling
1) After assembling the upper unit in the base
unit, mount both arms first. Mount the arm
so that the outer area of the arm shaft
touches the contact area
unit.
Figure 3-617
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
2
of the upper
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
2) Then mount the hinge, verify that the right
and left dampers are correct and mount
them.
Do not open the upper unit before
mounting the dampers. It is dangerous
because the dampers do not work when
the upper unit is closed.
3) Install the coil spring when the upper unit is
open. Since the spring has a strong ten-
sion, hold the spring firmly and install the
front shaft on the side plate. Align the di-
rection of the D-shape with the notch of the
arm of the rear shaft.
Verify that the grooves of the front and rear
shafts fit into the side plate.
4) After assembly, ensure that the upper unit
is opened and closed correctly.
3-45