7. Tray Guide

Note: The right tray guide is shown here.
Remove the left tray guide by referring
to the following procedure.
1) Remove the pickup tray unit.
(Page 3-6)
2) Remove the screw
remove the leaf spring
screws
3
(M3, TP head, self-tapping)
and remove the holder
5
.
Note: When the holder is removed, the coil
spring inside is detached.
Figure 3-221
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
(M3, round tip) and
2
. Then, remove 3
4
and tray guide
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
Notes on assembling
When the coil spring
holder, insert a tool with a thin and flat tip
from the rear side of the hole
the coil spring as shown in the figure below.
Mount the holder with this condition and fix
it with screws.
Figure 3-222
1
is mounted in the
2
, and clip