CHAPTER 3 DISASSEMBLY & REASSEMBLY

4. Top Cover

1) Remove the right and left covers.
2) Remove screw
1
unhooking 2 pairs of the fitting parts
remove the top cover
Figure 3-211
3-6
(round tips), and while
2
3
.
COPYRIGHT © CANON ELECTRONICS INC. 2008

5. Pickup Tray Unit

1) Remove the right and left covers.
2) Remove the screw
,
remove the lock shaft
3
(M3, round tips), and while unhooking
2 pairs of the fitting parts
cover
5
. In the same way, remove the
lock shaft and the cover on the opposite
side.
Note: A light guide for the sensor is built in the
right cover.
3) Lift and remove the pickup tray unit
along the guide.
Note: When the coil spring
and the shaft
to remove the pickup tray unit. Refer to
the "VI. 4. Entire Upper Unit" section.
1
(TP head) and
2
. Remove screw
4
, remove the
Figure 3-212
2
is removed
3
is removed, it is easier
Figure 3-213
CANON DR-X10C FIRST EDITION