21) Inspection of PTT Fluid Quantity

Fully tilt up outboard motor and lock with tilt stopper 1.
1.
Be sure to lock outboard motor with tilt
stopper after fully tilting up. Leaving
outboard motor without locking may lead to
accidental descent due to reduction of PTT
hydraulic pressure.
Remove reserve tank cap 2 and check quantity of PTT fluid
2.
contained in the tank.
Check PTT fluid level with outboard motor
fully tiled up. Removing reserve tank cap at
halfway position can cause blasting out of
PTT fluid, which is dangerous, and also
result in inaccurate fluid level reading.
Quantity of PTT fluid is normal when some fluid
spills out of cap hole when cap is removed.
3.
Add recommended PTT fluid to specified level if it is lacking.
Recommended PTT Fluid :
OIL
ATF DEXRON III
Attach reserve tank cap 2 and tighten to specified torque.
4.
Reserve Tank Cap :
1.5 N·m ( 1.1 lb·ft) [ 0.15 kgf·m ]