U2 Fault Trace List - YASKAWA F7 User Manual

Hide thumbs Also See for F7:
Table of Contents

Advertisement

http://www.aotewell.com

U2 Fault Trace List

After viewing the "Monitor" parameter list, follow the key operations below (Fig 3.4) to access the "Fault Trace" parameter
list.
-DRIVE-
Monitor
U1-01=
- - - - - - - - - - - - - - - - - - - -
U1-02=
U1-03=
Use
and
keys to scroll through the U2 "Fault Trace" parameter list.
Tel: +(86) 755 8660 6182
Rdy
0.00Hz
0.00Hz
0.00A
Fig 3.4 U2 Fault Trace List Access Procedure
Table 3.9 U2 Fault Trace List
Fault Trace Parameters
U2-01
Current Fault
U2-02
Previous Fault
U2-03
Frequency Reference at Fault*
U2-04
Output Frequency at Fault*
U2-05
Output Current at Fault*
U2-06
Motor Speed at Fault*
U2-07
Output Voltage at Fault*
U2-08
DC Bus Voltage at Fault*
U2-09
Output Power at Fault*
U2-10
Torque Reference at Fault
U2-11
Input Terminal Status at Fault*
U2-12
Output Terminal Status at Fault*
U2-13
Drive Operation Status at Fault*
U2-14
Cumulative Operation Time at Fault*
* Represents fault condition prior to current fault state.
Note: Fault trace is not executed at CPF00, CPF01,
CPF03, UV1, and UV2.
Digital Operator 3 - 9
Aotewell
-DRIVE-
Rdy
Fault Trace
U2-01=
None
- - - - - - - - - - - - - - - - - - - -
U2-02=
None
U2-03=
0.00Hz
Aotewell
Email: Sales@aotewell.com
-DRIVE-
U2-01=
- - - - - - - - - - - - - - - - - - - -
U2-02=
U2-03=
http://www.aotewell.com
Rdy
Current Fault
None
None
0.00Hz

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents