V/F Pattern For 200V Class Drives - YASKAWA F7 User Manual

Hide thumbs Also See for F7:
Table of Contents

Advertisement

http://www.aotewell.com
Table 5.6 lists the factory settings of V/F patterns when open loop vector or flux vector control method is selected
(A1-02 = 2 or 3).
Parameter No.
Max. Output
E1-04
Frequency
E1-05
Max. Output Voltage
E1-06
Base Frequency
Mid. Output
E1-07
Frequency
E1-08
Mid. Output Voltage
Min. Output
E1-09
Frequency
E1-10
Min. Output Voltage
1. For 400V class units, the voltage values are twice that of 200V class units.
2. These default values are for open loop vector or flux vector control methods (A1-02 = 2 or 3)
Tel: +(86) 755 8660 6182
Aotewell
Table 5.6 V/F Pattern for 200V Class Drives
Name
Basic Programming 5 - 19
Aotewell
Email: Sales@aotewell.com
Factory Setting
Unit
Open Loop Vector
Hz
60.0
V
230.0
Hz
60.0
V
3.0
V
12.6
Hz
0.5
V
2.3
http://www.aotewell.com
Flux Vector
60.0
230.0
60.0
0.0
0.0
0.0
0.0