Parameter
Parameter Name
No.
Digital Operator Display
Input Voltage Setting
E1-01
Input Voltage
V/F Pattern Selection
E1-03
V/F Selection
Maximum Output Frequency
E1-04
Max Frequency
Maximum Output Voltage
E1-05
Max Voltage
Base Frequency
E1-06
Base Frequency
Minimum Output Frequency
E1-09
Min Frequency
Base Voltage
E1-13
Base Voltage
Motor Rated Current
E2-01
Motor Rated FLA
Number of Motor Poles
E2-04
Number of Poles
Motor Rated Output
E2-11
Motor Rated Power
PG Parameter
F1-01
PG Pulse/Rev
Denotes that parameter can be changed when the Drive is running.
Tel: +(86) 755 8660 6182
Aotewell
Description
Set to the nominal voltage of the incoming line, sets maximum/
base voltage used by preset V/F patterns (E1-03 = 0 to E), adjusts
the levels of Drive protective features (i.e. Overvoltage, braking
resistor turn-on, stall prevention, etc.).
Set to the type of motor being used and the type of application.
The Drive operates utilizing a set V/F pattern to determine the
appropriate output voltage level for each commanded speed. There
are 15 different preset V/F patterns to select from (E1-03 = 0 to E)
with varying voltage profiles, base levels (base level = frequency
at which maximum voltage is reached), and maximum frequencies.
There are also settings for Custom V/F patterns that will use the
settings of parameters E1-04 through E1-13. E1-03 = F selects a
custom V/F pattern with an upper voltage limit and E1-03 = FF selects
a custom V/F pattern without an upper voltage limit.
0: 50Hz
1: 60Hz
2: 60Hz (50Hz Base)
3: 72Hz (60Hz Base)
4: 50Hz VT1
5: 50Hz VT2
6: 60Hz VT1
7: 60Hz VT2
8: 50Hz HST1
9: 50Hz HST2
A: 60Hz HST1
B: 60Hz HST2
C: 90Hz (60Hz Base)
D: 120Hz (60Hz Base)
E: 180Hz (60Hz Base)
F: Custom V/F
FF:Custom w/o limit
These parameters are only applicable when V/F Pattern Selection
is set to Custom (E1-03 = F or FF). To set V/F characteristics in a
straight line, set the same values for E1-07 and E1-09. In this case,
the setting for E1-08 will be disregarded. Always ensure that the
four frequencies are set in the following manner:
E1-04 ≥ E1-12 ≥ E1-06 > E1-07 ≥ E1-09
E2-04 is automatically set during Auto-Tuning.
Output voltage (V)
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09
E1-07
Frequency (Hz)
Set to the motor rated power in KW.
This value is automatically set during Auto-Tuning.
Sets the number of pulses per revolution of the encoder (pulse
generator). This value is automatically set during Auto-Tuning.
Start-Up 4 - 13
Aotewell
Email: Sales@aotewell.com
Setting
Range
155 to
255.0
(240V)
310 to
510.0
(480V)
0 to FF
HD: 40.0
to 300.0
ND2: 40.0
to 400.0
0 to 255.0
(240V)
0 to 510.0
(480V)
0.0 to
200.0
0.0 to
200.0
0 to 255.0
(240V)
0 to 510.0
(480V)
Varies by
kVA
E1-06
E1-11 E1-04
2 to 48
0.00 to
650.00
0 to 60000
http://www.aotewell.com
Control Method
Factory
V/F
Setting
V/F
w/
OLV
PG
240V
Q
Q
Q
480V
F
Q
Q
-
60.0Hz
Q
Q
Q
240V
Q
Q
Q
480V
60.0Hz
Q
Q
Q
1.5Hz
Q
Q
Q
0.0VAC
A
A
Q
Varies by
Q
Q
Q
kVA
4
-
Q
-
Varies by
Q
Q
Q
kVA
1024
-
Q
-
FV
Q
-
Q
Q
Q
A
Q
Q
Q
Q
Q