Parameter
Parameter Name
No.
Digital Operator Display
C1-01
Acceleration Time 1
Accel Time 1
C1-02
Deceleration Time 1
Decel Time 1
C1-03
Acceleration Time 2
Accel Time 2
C1-04
Deceleration Time 2
Decel Time 2
Acceleration Time 3
C1-05
Accel Time 3
Deceleration Time 3
C1-06
Decel Time 3
Acceleration Time 4
C1-07
Accel Time 4
Deceleration Time 4
C1-08
Decel Time 4
Fast Stop Time
C1-09
Fast Stop Time
Accel/Decel Time Setting
C1-10
Unit
Acc/Dec Units
Accel/Decel
C1-11
Switch Frequency
Acc/Dec SW Freq
S-Curve Characteristic at
C2-01
Accel Start
SCrv Acc @ Start
S-Curve Characteristic at
C2-02
Accel End
SCrv Acc @ End
S-Curve Characteristic at
C2-03
Decel Start
SCrv Dec @ Start
S-Curve Characteristic at
C2-04
Decel End
SCrv Dec @ End
Denotes that parameter can be changed when the Drive is running.
* For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0.
Tel: +(86) 755 8660 6182
Aotewell
Table A.1 F7 Parameter List (Continued)
Description
Accel / Decel
Sets the time to accelerate from zero to maximum frequency.
Sets the time to decelerate from maximum frequency to zero.
Sets the time to accelerate from zero to maximum frequency when
selected via a multi-function input.
Sets the time to decelerate from maximum frequency to zero when
selected via a multi-function input.
Sets the time to accelerate from zero to maximum frequency when
selected via a multi-function input.
Sets the time to decelerate from maximum frequency to zero when
selected via a multi-function input.
Sets the time to accelerate from zero to maximum frequency when
selected via a multi-function input.
Sets the time to decelerate from maximum frequency to zero when
selected via a multi-function input.
Sets the time to decelerate from maximum frequency to zero for the
multi-function input "Fast Stop" function.
Sets the setting resolution of C1-01 to C1-09
0: 0.01 sec (0.00 to 600.00 sec)
1: 0.1 sec (0.0 to 6000.0 sec)
Sets the frequency for automatic switching of accel / decel times.
Fout < C1-11: Accel/Decel Time 4
Fout ≥ C1-11: Accel/Decel Time 1
Multi-function inputs "Multi-Acc/Dec 1" and "Multi-Acc/Dec 2"
have priority over C1-11.
S-Curve Accel / Decel
S-curve is used to further soften the starting and
stopping ramp. The longer the S-curve time, the
softer the starting and stopping ramp.
Run
command
ON
Output frequency
C2-02
C2-01
Parameters A - 9
Aotewell
Email: Sales@aotewell.com
Setting
Range
0.0
to
6000.0
0.0
to
6000.0
0 to 1
Varies
by
Duty
Rating*
OFF
0.00 to
2.50
C2-03
C2-04
Time
Control Method
Factory
V/F
Setting
V/F
w/PG
Q
Q
Q
Q
A
A
A
A
10.0sec
A
A
A
A
A
A
A
A
10.0sec
A
A
1
A
A
0.0Hz
A
A
0.20sec
A
A
0.20sec
A
A
0.20sec
A
A
0.00sec
A
A
http://www.aotewell.com
Open
Flux
Loop
Vector
Vector
Q
Q
Q
Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

Hide quick links: