YASKAWA F7 User Manual page 173

Hide thumbs Also See for F7:
Table of Contents

Advertisement

http://www.aotewell.com
Parameter
Parameter Name
No.
Digital Operator Display
Dwell Reference at Start
b6-01
Dwell Ref @Start
Dwell Time at Start
b6-02
Dwell Time @Start
Dwell Frequency at Stop
b6-03
Dwell Ref @Stop
Dwell Time at Stop
b6-04
Dwell Time @Stop
b7-01
Droop Control Level
Droop Quantity
b7-02
Droop Control Delay Time
Droop Delay Time
Energy Saving Control
b8-01
Selection
Energy Save Sel
Energy Saving Gain
b8-02
Energy Save Gain
Energy Saving Control Filter
b8-03
Time Constant
Energy Saving F.T
Energy Saving
b8-04
Coefficient Value
Energy Save COEF
Power Detection Filter Time
b8-05
kW Filter Time
Search Operation Voltage
b8-06
Limit
Search V Limit
Zero Servo Gain
b9-01
Zero Servo Gain
Zero Servo Completion Width
b9-02
Zero Servo Count
Denotes that parameter can be changed when the Drive is running.
Tel: +(86) 755 8660 6182
Aotewell
Table A.1 F7 Parameter List (Continued)
Description
Reference Hold (Dwell)
Temporarily holds the frequency reference.
Run command
OFF
ON
Output frequency
b6-01
b6-03
b6-02
Droop Control
Sets the speed decrease as a percentage of maximum output
frequency (E1-04) when the motor is at 100% load torque. Setting
of 0.0 disables droop control.
Determines the droop control delay time in response to a load
change.
Energy Saving
Energy Savings function enable/disable selection.
0: Disabled
1: Enabled
Sets energy savings control gain when in vector control method.
Sets energy saving control filter time constant when in vector
control method.
Used to fine-tune the energy savings function when in V/F control
method.
Zero Servo
Sets the position loop gain for Zero Servo command.
This function is effective when multi-function input "zero
servo command" is set.
Sets number of pulses used for the multi-function output of
"zero servo completion".
Parameters A - 8
Aotewell
Email: Sales@aotewell.com
Setting
Range
0.0 to
400.0
0.0 to
10.0
0.0 to
400.0
0.0 to
Time
10.0
b6-04
0.0 to
100.0
0.03 to
2.00
0 to 1
0.0 to
10.0
0.00 to
10.00
0.0 to
655.00
0 to 2000
0 to 100
0 to 100
0 to
16383
http://www.aotewell.com
Control Method
Factory
Open
V/F
Setting
V/F
Loop
w/PG
Vector
0.0Hz
A
A
A
0.0sec
A
A
A
0.0Hz
A
A
A
0.0sec
A
A
A
0.0%
-
-
-
0.05sec
-
-
-
0
A
A
A
1.0
-
-
A
Varies
by
-
-
A
kVA
Varies
by
A
A
-
kVA
20ms
A
A
-
0%
A
A
-
5
-
-
-
10
-
-
-
pulses
Flux
Vector
A
A
A
A
A
A
A
A
A
-
-
-
A
A