High Slip Braking
Deceleration Frequency
n3-01
Width
HSB Decel Width
High Slip Braking
n3-02
Current Limit
HSB Current Ref
High Slip Braking Dwell
n3-03
Time at Stop
HSB DwelTim@ Stp
High Slip Braking
n3-04
Overload Time
HSB OL Time
o1-01
User Monitor Selection
User Monitor Sel
User Monitor Selection After
o1-02
Power-Up
Power-On Monitor
Digital Operator Display
o1-03
Selection
Display Scaling
Setting unit for frequency
parameters related to V/F
o1-04
characteristics
Display Units
LCD Brightness
o1-05
Adjustment
LCD Contrast
Denotes that parameter can be changed when the Drive is running.
Tel: +(86) 755 8660 6182
Aotewell
Table A.1 F7 Parameter List (Continued)
Description
High Slip Braking
Sets how aggressively the Drive decreases the output frequency as
it stops the motor using high slip braking (HSB). If Overvoltage
(OV) faults occur during HSB, this parameter may need to be
increased.
Sets the maximum current to be drawn during an HSB stop. Higher
n3-02 settings will shorten motor stopping times but cause
increased motor current, and therefore increased motor heating.
Sets the amount of time the Drive will dwell at E1-09 (Minimum
Frequency) at the end of deceleration. If this time is set too low, the
machine inertia can cause the motor to rotate slightly after the HSB
stop is complete and the Drive output is shut off.
Sets the time required for an HSB overload fault (OL7) to occur
when the Drive output frequency does not change for some reason
during an HSB stop. Normally this does not need to be adjusted.
Monitor Select
Selects which monitor will be displayed in the operation menu upon
power-up when o1-02 = 4.
Selects which monitor will be displayed upon
power-up.
1: Frequency Reference (U1-01)
2: Output Frequency (U1-02)
3: Output Current (U1-03)
4: User Monitor (set by o1-01)
Sets the units of the Frequency References (d1-01 to
d1-17), the Frequency Reference Monitors (U1-01,
U1-02, U1-05), and the Modbus communication
frequency reference.
0: Hz
1: % (100% = E1-04)
2 to 39: RPM (Enter the number of motor poles).
40 to 39999: User display.
Set the number desired at maximum
output frequency.
4 digit number
Number of digits from the right of the
decimal point
Example 1: o1-03 = 12000, will result in frequency
reference from 0.0 to 200.0 (200.0 = Fmax).
Example 2: o1-03 = 21234, will result in frequency
reference from 0.00 to 12.34 (12.34 = Fmax).
Sets the setting units related to V/F pattern frequency related
parameters (E1-04, -06, -09, -11)
0: Hertz
1: RPM
Sets the contrast of the Digital Operator LCD. A setting of "1" is the
lightest contrast and a setting of "5" is the darkest contrast.
Parameters A - 35
Aotewell
Email: Sales@aotewell.com
Control Method
Setting
Factory
V/F
Range
Setting
V/F
w/PG
1 to 20
5%
A
100 to
150%
A
200
0.0 to
1.0sec
A
10.0
30 to
40sec
A
1200
4 to 45
6
A
1 to 4
1
A
0 to
0
A
39999
0 to 1
0
-
0 to 5
3
A
http://www.aotewell.com
Open
Flux
Loop
Vector
Vector
A
-
-
A
-
-
A
-
-
A
-
-
A
A
A
A
A
A
A
A
A
-
-
A
A
A
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents