F7 Parameter List - YASKAWA F7 User Manual

Hide thumbs Also See for F7:
Table of Contents

Advertisement

http://www.aotewell.com

F7 Parameter List

Parameter
Parameter Name
No.
Digital Operator Display
A1-00
Language Selection
Select Language
A1-01
Access Level Selection
Access Level
Control Method Selection
A1-02
Control Method
Initialize Parameters
A1-03
Init Parameters
Password 1
A1-04
Enter Password
Password 2
A1-05
Select Password
User Parameter 1
A2-01
User Param 1
User Parameter 2
A2-02
User Param 2
User Parameter 3
A2-03
User Param 3
User Parameter 4
A2-04
User Param 4
User Parameter 5
A2-05
User Param 5
User Parameter 6
A2-06
User Param 6
User Parameter 7
A2-07
User Param 7
User Parameter 8
A2-08
User Param 8
User Parameter 9
A2-09
User Param 9
Denotes that parameter can be changed when the Drive is running.
Tel: +(86) 755 8660 6182
Aotewell
Table A.1 F7 Parameter List
Description
Initialization
Language selection for the Digital Operator.
This parameter is not reset to the factory setting by A1-03.
0: English
1: Japanese
2: Deutsch
3: Francais
4: Italiano
5: Espanol
6: Portugues
Selects which parameters are accessible via the Digital Operator.
0: Operation Only
1: User Level (only available if A2 parameters have been set)
2: Advanced Level
Selects the Control Method of the Drive.
0: V/F control without PG
1: V/F control with PG
2: Open Loop Vector
3: Flux Vector (Closed Loop Vector)
Used to return all parameters to their factory or user default
settings. (Initializes and then returns A1-03 to zero.)
0: No Initialize
1110: User Initialize (The user must first set their own parameter
values and then store them using parameter o2-03.)
2220: 2-Wire Initialization
3330: 3-Wire Initialization
When the value set into A1-04 does NOT match the value set into
A1-05, parameters A1-01 thru A1-03 and A2-01 thru A2-32 cannot
be changed. All other parameters as determined by A1-01 can be
changed. Parameter A1-05 can be accessed by pressing the MENU
key while holding the RESET key.
User Parameters
Selects the parameters to be available in the User Access Level
(A1-01 = 1). These parameters are not related to the User Initialize
function.
Parameters A - 3
Aotewell
Email: Sales@aotewell.com
Setting
Factory
V/F
Range
Setting
V/F
w/PG
0 to 6
0
A
0 to 2
2
A
0 to 3
2
Q
0 to
0
A
3330
0 to 9999
0
A
0 to 9999
0
A
A
A
A
A
b1-01
to
A
o3-02
A
A
A
A
http://www.aotewell.com
Control Method
Open
Flux
Loop
Vector
Vector
A
A
A
A
A
A
Q
Q
Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents