Parameter
Parameter Name
No.
Digital Operator Display
Copy Function Selection
o3-01
Copy Function Sel
Copy Allowed Selection
o3-02
Read Allowable
Motor Selection 1 / 2
T1-00
Select Motor
Auto-Tuning mode selection
T1-01
Tuning Mode Sel
Motor Rated Power
T1-02
Mtr Rated Power
Motor rated voltage
T1-03
Rated Voltage
Motor Rated Current
T1-04
Rated Current
Motor Base Frequency
T1-05
Rated Frequency
Number of Motor Poles
T1-06
Number of Poles
Motor Base Speed
T1-07
Rated Speed
Number of PG Pulses
T1-08
PG Pulses / Rev
Denotes that parameter can be changed when the Drive is running.
* For Heavy Duty (HD) Rating: Setting Range=0.0 to 300.0. For Normal Duty (ND) Rating: Setting Range=0.0 to 400.0.
Tel: +(86) 755 8660 6182
Aotewell
Table A.1 F7 Parameter List (Continued)
Description
COPY Function
This parameter controls the copying of parameters to and from the
Digital Operator.
0: COPY SELECT (no function)
1: INV -> OP READ -
All parameters are copied from the
Drive to the Digital Operator.
2: OP -> INV WRITE -
All parameters are copied from the
Digital Operator to the Drive.
3: OP<-->INV VERIFY -
Parameter settings in the Drive are
compared to those in the Digital Oper-
ator.
NOTE: When using the copy function, the Drive model number
(o2-04), software number (U1-14), and control method
(A1-02) must match or an error will occur.
Enables and disables the Digital Operator copy functions.
0: Disabled - No Digital Operator copy functions are allowed.
1: Enabled - Copying allowed.
Auto-Tuning
Selects which set of motor parameters are to be used and set during
Auto-Tuning. If Motor 2 selection (H1-XX=16) is not selected, this
parameter will not be displayed.
1: 1st Motor - E1 to E2
2: 2nd Motor - E3 to E4
Selects the Auto-Tuning mode.
0: Rotational Auto-Tuning (A1-02 = 2 or 3)
1: Stationary Auto-Tuning (A1-02 = 2 or 3)
2: Terminal resistance only, (stationary) Auto-Tuning
(A1-02 = 0, 1, 2, or 3)
Set the motor rated power in kilowatts (kW).
NOTE:If motor power is given in horsepower, power in kW can be
calculated using the following formula: kW = Hp * 0.746
Set the motor rated voltage in Volts (V).
Set the motor rated current in Amperes (A).
Set the base frequency of the motor in Hertz (Hz).
Set the number of motor poles.
Set the base speed of the motor in revolutions per minute (RPM).
Set the number of pulses per revolution (PPR) for the encoder
(pulse generator) being used without any multiplication factor.
Parameters A - 37
Aotewell
Email: Sales@aotewell.com
Setting
Factory
V/F
Range
Setting
V/F
w/PG
0 to 3
0
A
0 to 1
0
A
1, 2
1
A
0 to 2
0
A
0.00 to
Varies
650.00
by
A
kW
kVA
0.0 to
255.0
(240V)
230Vac
or
-
0.0 to
460Vac
510.0
(480V)
Varies
Varies by
by
A
kVA
kVA
Varies
by
60.0Hz
-
Duty
Rating*
2 to 48
4 poles
-
0 to
1750
-
24000
RPM
0 to
1024
-
60000
PPR
http://www.aotewell.com
Control Method
Open
Flux
Loop
Vector
Vector
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
-
A
A
A
A
A
-
A
A
-
A
A
-
A
A
-
-
A