Drive Output Specifications; 208-240Vac - YASKAWA F7 User Manual

Hide thumbs Also See for F7:
Table of Contents

Advertisement

http://www.aotewell.com

Drive Output Specifications

The standard Drive specifications are listed in the following tables.

208-240Vac

Model Number CIMR-F7U
Rated output
capacity (kVA)
*2
Horsepower
Rated output
current (A)
*3
Overload capacity
(% of rated output
current for 60 sec.)
Current limit (% of
rated output current)
*4
Carrier frequency
Maximum output
frequency
Rated output
capacity (kVA)
*2
Horsepower
Rated output
current (A)
*3
Overload capacity
(% of rated output
current for 60 sec.)
Current limit (% of
rated output current)
Carrier frequency
*5
(kHz)
Maximum output
frequency
Maximum output voltage
*1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and
maximum output frequency. Parameter C6-01 must be set to value of "0" for Heavy Duty ratings and "2" for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0).
*2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor
and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current.
*3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of
rated output current for 45 seconds and a current limit rating of 150%.
*4 When setting the carrier frequency above the factory default, the Drive must be derated.
*5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher.
Tel: +(86) 755 8660 6182
Table i.2 208-240Vac Drive Specifications
20P4
20P7 21P5
22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037
1.2
1.6
2.7
3.7
0.5/0.75
1
2
3
3.2
4.2
7.0
9.6
1.4
1.8
3.0
4.1
0.5/0.75
1
2
3
3.6
4.6
7.8
10.8 16.8 23.0 31.0 46.2 59.4 74.8 88.0 115.0 162.0 192.0 215
107
107
108
107
10
10
10
8
Aotewell
208-240Vac
5.7
8.8
12.0 17.0 22.0 27.0 32.0 44.0 55.0
5
7.5
10
15
20
15.2 23.0 31.0 45.0 58.0
150
150
2kHz
300.0Hz
6.4
8.8
12.0 18.0 23.0 29.0 34.0 44.0 62.0
5
7.5
10
15
20
107
120
120
117
117
10
15
15
8
10
400.0Hz
3-phase; 200, 208, 220, 230, or 240Vac
(Proportional to input voltage)
iv
Aotewell
Email: Sales@aotewell.com
2045 2055
69.0
25
30
40
50
60
71
85.0 115.0 145.0 180.0 215
73.0
25
30
40
50/60
75
114
116
120
107
113
120
10
10
10
5
http://www.aotewell.com
208-230Vac
2075
2090 2110
82.0
110.0
130.0 140.0
75
100
125
150
283.0
346.0 360.0
138
138
82.0
120.0
140.0 160.0
75
100/125 150
150
312.0
360.0 415.0
120
109
115
120
5
8
2
2
*5
*3
*3
2

Hide quick links: