Parameter
Parameter Name
No.
Digital Operator Display
Motor Rated Current
E2-01
Motor Rated FLA
Motor Rated Slip
E2-02
Motor Rated Slip
Motor No-Load Current
E2-03
No-Load Current
Number of Motor Poles
E2-04
Number of Poles
Motor Line-to-Line
E2-05
Resistance
Term Resistance
Motor Leakage Inductance
E2-06
Leak Inductance
Motor Iron-core
E2-07
Saturation Coefficient 1
Saturation Comp 1
Motor Iron-core
E2-08
Saturation Coefficient 2
Saturation Comp 2
Motor Mechanical Loss
E2-09
Mechanical Loss
Motor Iron Loss for Torque
E2-10
Compensation
Tcomp Iron Loss
Motor Rated Output
E2-11
Mtr Rated Power
Motor Iron-Core
E2-12
Saturation Coefficient 3
Saturation Comp 3
Denotes that parameter can be changed when the Drive is running.
Tel: +(86) 755 8660 6182
Aotewell
Table A.1 F7 Parameter List (Continued)
Description
Motor Setup
Set to the motor nameplate full load current in amperes (A). This
value is automatically set during Auto-Tuning.
Set to the motor rated slip in hertz (Hz).
This value is automatically set during rotational Auto-Tuning.
Set to the magnetizing current of the motor as a percentage of full
load amps (E2-01). This value is automatically set during rotational
Auto-Tuning.
Set to the number of motor poles.
This value is automatically set during Auto-Tuning.
Set to the phase-to-phase motor resistance in ohms (Ω).
This value is automatically set by Auto-Tuning.
Set to the voltage drop due to motor leakage inductance as a
percentage of motor rated voltage.
This value is automatically set during Auto-Tuning.
Set to the motor iron saturation coefficient at 50% of magnetic flux.
This value is automatically set during rotational Auto-Tuning.
Set to the motor iron saturation coefficient at 75% of magnetic flux.
This value is automatically set during rotational Auto-Tuning.
Set to the motor mechanical loss as a percentage of motor rated
power (kW) capacity.
Adjust in the following circumstances:
• When torque loss is large due to motor bearing friction.
• When the torque loss in the load is large.
Set to the motor iron loss in watts (W).
Set to the motor rated power in kilowatts (kW).
This value is automatically set during Auto-Tuning.
1HP = 0.746kW
Set to the motor iron saturation coefficient at 130% of magnetic
flux.
This value is automatically set during rotational Auto-Tuning.
Parameters A - 16
Aotewell
Email: Sales@aotewell.com
Control Method
Setting
Factory
V/F
Range
Setting
V/F
w/PG
Varies
Varies by
by
Q
Q
kVA
kVA
Varies
Varies by
by
A
A
kVA
kVA
Varies
Varies by
by
A
A
kVA
kVA
2 to 48
4
-
Q
Varies
0.000 to
by
A
A
65.000
kVA
Varies
0.0 to
by
-
40.0%
kVA
0.00 to
0.50
-
0.50
0.50 to
0.75
-
0.75
0.0 to
0.0%
-
10.0
Varies
0 to
by
A
A
65535 W
kVA
0.00 to
Varies
650.00
by
Q
Q
kW
kVA
0.0 to
1.30
-
1.60
http://www.aotewell.com
Open
Flux
Loop
Vector
Vector
Q
Q
A
A
A
A
-
Q
A
A
-
A
A
-
A
A
-
A
A
-
A
A
-
-
Q
Q
-
A
A