Standard Drive Specifications

The standard Drive specifications are listed in the following tables.
208-240Vac
Model Number CIMR-
20P4
F7U
Rated output
capacity (kVA)
*2
0.5/0.75
Horsepower
Rated output
current (A)
*3
Overload capacity
(% of rated output
current for 60 sec)
Current limit (% of
rated output current)
*5,*7
Carrier frequency
Maximum output
frequency
Rated output
capacity (kVA)
*2
0.5/0.75
Horsepower
Rated output
current (A)
*3
Overload capacity
(% of rated output
current for 60 sec.)
Current limit (% of
rated output current)
Carrier frequency
*6
(kHz)
Maximum output
frequency
Maximum output
voltage
Rated voltage
Rated frequency
Rated input current -
*1
Heavy Duty
(A)
Rated input current -
*1
Normal Duty
(A)
Allowable voltage
fluctuation
Allowable frequency
fluctuation
DC
Reactor
Measures
for power
supply
harmonics
12-Pulse
Rectification
*1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and maxi-
mum output frequency. Parameter C6-01 must be set to value of "0" for Heavy Duty ratings and "2" for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0).
*2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive,
be sure that the Drive's rated output current is appropriate for the motor's rated current.
*3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of rated output
current for 45 seconds and a current limit rating of 150%.
*4 When setting the carrier frequency above the factory default, the Drive must be derated.
*5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher.
*6 Each value shown is the Maximum carrier frequency and default carrier frequency.
*7 The carrier frequency for Heavy Duty is default to 2 kHz. Software version VSF103021 and higher may allow the carrier frequency to be increased above 2 kHz with a reduction in
continuous rated output current. Refer to C6-02 in Chapter 5 for further details.
Tel: +(86) 755 8660 6182
Table C.1 208-240Vac Drive Specifications
208-240Vac Drives
20P7
21P5
22P2 23P7 25P5 27P5 2011 2015 2018 2022
1.2
1.6
2.7
3.7
1
2
3
3.2
4.2
7.0
9.6
15.2
1.4
1.8
3.0
4.1
1
2
3
3.6
4.6
7.8
10.8
16.8
107
107
108
107
10
10
10
8
3-phase, 200/208/220/230/240Vac, 50/60Hz
3.8
4.9
8.4
11.5
4.3
5.5
9.4
13
Optional
Not possible
Aotewell
5.7
8.8
12.0
17.0 22.0 27.0 32.0
5
7.5
10
15
20
23.0
31.0
45.0 58.0
150
150
2kHz
300.0Hz
6.4
8.8
12.0
18.0 23.0 29.0 34.0
5
7.5
10
15
20
23.0
31.0
46.2 59.4 74.8 88.0 115.0 162.0 192.0
107
120
120
117
117
120
10
15
15
8
10
400.0Hz
3-phase; 200, 208, 220, 230, or 240Vac
(Proportional to input voltage)
18
24
37
52
68
20
24
37
53
70
+ 10%, - 15%
±5%
Specifications C - 2
Aotewell
Email: Sales@aotewell.com
208-230Vac Drives
2030
2037
2045
44.0
55.0
69.0
25
30
40
50
60
71
85.0 115.0 145.0 180.0
44.0
62.0
73.0
25
30
40
50/60
75
114
116
120
107
113
10
10
10
5
5
3-phase, 200/208/220/230Vac, 50/60Hz
84
94
120
160
198
89
98
120
180
212
Possible
http://www.aotewell.com
2055
2075
2090 2110
82.0
110.0
130.0 140.0
75
100
125
150
215
283.0
346.0 360.0
*3
138
*3
138
82.0
120.0
140.0 160.0
-
100/125
150
-
215
312.0
360.0 415.0
120
109
115
120
8
2
2
2
237
317
381
396
237
350
396
457
Built-in
*4
*5