Parameter
Parameter Name
No.
Digital Operator Display
DO-08 Channel 8 Output
F5-08
Selection
DO Ch8 Select
DO-08 Output Mode
F5-09
Selection
DO-08 Selection
Operation Selection after
F6-01
Communication Error
Comm Bus Flt Sel
Selection of External Fault
from Communication Option
F6-02
Board
EF0 Detection
Stopping Method for
External Fault from
F6-03
Communication Option Board
EF0 Fault Action
Trace Sampling from
Communications Option
F6-04
Board
Trace Sample Tim
Current Monitor Display Unit
F6-05
Selection
Current Unit Sel
Torque Reference/Torque
Limit Selection from
F6-06
Communications Option
Torq Ref/Lmt Sel
Denotes that parameter can be changed when the Drive is running.
Tel: +(86) 755 8660 6182
Aotewell
Table A.1 F7 Parameter List (Continued)
Description
Sets the digital output function number for channel 8. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.
Sets the function of the DO-08 digital output option board.
0: 8-channel individual outputs.
1: Binary code output.
2: 8-channel Selected - Output according to F5-01 to F5-08
settings.
Communications Option Setup
Selects the stopping method for a communication option board fault
(BUS). Active only when a communication option board is installed
and b1-01 or b1-02 = 3.
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
Selects the condition in which an EF0 fault is detected from a
communication option board. Active only when a communication
option board is installed and b1-01 or b1-02 = 3.
0: Always detected
1: Detected only during operation
Selects the stopping method for an external fault from a
communication option board (EF0). Active only when a
communication option board is installed and b1-01 or b1-02 = 3.
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
Sets the sample trace for the CP-916 option board.
Selects the current monitor scaling when using a communication
option board.
0: Displayed in Amps
1: 100%/8192 (12 bit binary number with 8192=100% Drive's rated
current)
Selects torque reference/limit when using communications option
board.
0: Disabled -Torque reference/limit from option board disabled
1: Enabled -Torque reference/limit from option board enabled.
Parameters A - 21
Aotewell
Email: Sales@aotewell.com
Control Method
Setting
Factory
V/F
Range
Setting
V/F
w/PG
0 to 38
F
A
A
0 to 2
0
A
A
0 to 3
1
A
A
0 to 1
0
A
A
0 to 3
1
A
A
0 to
0
A
A
60000
0 to 1
0
A
A
0 to 1
0
-
http://www.aotewell.com
Open
Flux
Loop
Vector
Vector
A
A
A
A
A
A
A
A
A
A
A
A
A
A
-
-
A